Netlite IT

  • COSA FACCIAMO
    • Sviluppo Software
    • Cloud
    • Consulenza Sistemistica
    • Sicurezza
    • Block Chain
    • Automazione Industriale
    • Jobs/Partnership
  • DOVE SIAMO
  • BLOG
  • CONTATTI
  • Newsletter
  • Home
  • Blog
  • Sistemistica
  • Esperimenti con multipath e SAN
23 Febbraio 2019

Esperimenti con multipath e SAN

Esperimenti con multipath e SAN

da netlite-team / venerdì, 07 Luglio 2017 / Pubblicato il Sistemistica, Tips & Tricks, vpn

http://www-01.ibm.com/support/docview.wss?uid=isg3T1011985
http://www.sysadminshare.com/2013/06/multipath-config-status-check-in-linux.html
https://access.redhat.com/documentation/en-US/Red_Hat_Enterprise_Linux/5/html-single/DM_Multipath/index.html#config_file_multipath

Multipath: Active/Passive, Dual Active, and Active/Active


https://serverfault.com/questions/288087/linux-multipath-not-using-all-paths-and-wont-use-queue-length-path-selector/355151
https://h50146.www5.hpe.com/products/software/oe/linux/mainstream/support/doc/option/fibre/pdfs/c02020121.pdf

grep mpt /sys/class/scsi_host/host?/proc_name

rescan-scsi-bus.sh

echo “- – -” > /sys/class/scsi_host/host1/scan
multipath -l

multipathd -k”fail path sdb”
multipathd -k”del path sdb”
multipathd -k”reinstate path sdb”
multipathd -k”show paths”

dmsetup remove /dev/mapper/MSA_BELLNET
dmsetup ls

echo 1 > /sys/block/sde/device/delete
echo 1 > /sys/block/sda/device/rescan

service multipath-tools restart

partprobe /dev/sdb
sfdisk -R /dev/sdb
partx -u /dev/sdb
blockdev –rereadpt /dev/mapper/MSA_BELLNET
partprobe -s

pvcreate –uuid “DMD39I-rIMF-vVUc-6KaY-li2N-SF4n-v38O5m” –restorefile /root/VG-BELL.vg /dev/disk/by-id/scsi-MSA_BELLNET
vgcfgbackup -f VG-BELL.vg VG-BELL
vgcfgrestore -f VG-BELL.vg VG-BELL

multipath.conf

defaults {
        polling_interval        15
        path_selector           "round-robin 0"
        path_grouping_policy    multibus
        prio                    const
        path_checker            directio
        rr_min_io               100
        flush_on_last_del       no
        max_fds                 8192
        rr_weight               priorities
        failback                immediate
        no_path_retry           fail
        queue_without_daemon    no
        user_friendly_names     yes
        mode                    644
        uid                     0
        gid                     disk
}
blacklist {
        devnode "^(ram|raw|loop|fd|md|dm-|sr|scd|st)[0-9]*"
        devnode "^hd[a-z]"
        devnode "^sda"
        devnode "^sda[0-9]"
        wwid    "3600508b1001c1f5b93df16da7e7ab72e"
        wwid    "3600508b1001c81da7e4515d6a1c3a693"
        wwid    "OCZ-VELO_DRIVE_OCZ-938561J47139J405"
        wwid    "OCZ-VELO_DRIVE_OCZ-ADU3LJ4GZL225676"
        wwid    "OCZ-VELO_DRIVE_OCZ-V98FXMA0Q041W67U"
#       wwid 3600c0ff0001432f020c55c5901000000
        device {
                vendor HP
                product "P410i|LOGICAL"
        }
}
devices {
        device {
                vendor                  "HP"
                product                 "P2000 G3*"
                path_grouping_policy    "group_by_prio"
#               uid_attribute           "ID_SERIAL"
                path_checker            "tur"
                path_selector           "round-robin 0"
                features                "0"
                hardware_handler        "0"
                prio                    "alua"
                rr_weight               "uniform"
                failback                "immediate"
                no_path_retry           18
                rr_min_io               100
        }
}
multipaths {
        multipath {
                wwid 3600c0ff00014e4ed9724235801000000
                alias MSA_NETLITE
        }
        multipath {
                wwid 3600c0ff00014e4edfa37695801000000
                alias MSA_NETLITE_BACKUP
        }
        multipath {
#               path_grouping_policy    multibus
                wwid 3600c0ff0001432f020c55c5901000000
                alias MSA_BELLNET
        }
        multipath {
                wwid 3600c0ff0001432f0a80e5a5901000000
                alias MSA_BELLNET_BACKUP
        }
}

andrea

  • Tweet
Taggato in: addtap, addtap.bat, contemporanee, multiple, openvpn, tap, tapinstall, vpn

Su netlite-team

Che altro puoi leggere

Profili Colore
Microserver N54L Firmware 2013
Cordova Phonegap installazione ed utilizzo in ambiente Android

Lascia un commento Annulla risposta

Il tuo indirizzo email non sarà pubblicato. I campi obbligatori sono contrassegnati *

Questo sito usa Akismet per ridurre lo spam. Scopri come i tuoi dati vengono elaborati.

Ricerca

Recent Posts

  • Autenticazione SSSD/LDAP su AD

    /etc/portage/package.use emerge sssd /etc/sshd/...
  • HP Tools per il controller SAS [SSACLI]

    Crea un file hp.list in /etc/apt/sources.list.d...
  • Reverse Proxy Apache HTTPS High Security and Mod_Security

    andrea...
  • Debian Bonding LACP con Switch HP 1820-24G

    Una volta configurato lo switch HP 1820-24G Swi...
  • Centos 7 Cluster PCS

    Installo due VM in VirtualBox identiche (4C, 4G...

Recent Comments

  • PROXMOX RAID Setup | netlite su PROXMOX tips

Archives

  • Febbraio 2019
  • Ottobre 2018
  • Settembre 2018
  • Aprile 2018
  • Agosto 2017
  • Luglio 2017
  • Giugno 2017
  • Aprile 2015
  • Dicembre 2014
  • Novembre 2014
  • Ottobre 2014
  • Settembre 2014
  • Agosto 2014
  • Giugno 2014
  • Marzo 2014
  • Febbraio 2014
  • Dicembre 2013
  • Settembre 2013
  • Agosto 2013
  • Luglio 2013
  • Giugno 2013
  • Maggio 2013

Categories

  • Android
  • APP
  • Cluster
  • Networking
  • Non categorizzato
  • Sistemistica
  • Tips & Tricks
  • Virtualizzazione
  • vpn
  • Windows

Meta

  • Accedi
  • RSS degli articoli
  • RSS dei commenti
  • WordPress.org

Featured Posts

  • Autenticazione SSSD/LDAP su AD

    0 commenti
  • HP Tools per il controller SAS [SSACLI]

    0 commenti
  • Reverse Proxy Apache HTTPS High Security and Mod_Security

    0 commenti
  • Debian Bonding LACP con Switch HP 1820-24G

    0 commenti
  • Centos 7 Cluster PCS

    0 commenti

NETLITE SNC

Corso Vittorio Emanuele II, 188
37069 Villafranca di Verona (VR)
C.C.I.A.A di Verona N.ro 364993
PIVA/CF 03782800233

Sedi Operative:
Via Roberto da Sanseverino, 95 38122 Trento (TN)
Via Walter Fleming, 13 37026 Settimo di Pescantina (VR)
Via Norberto Bobbio, 9 20096 Pioltello (MI)

Contatti

Tel: +39 045 4856656
Fax: +39 045 4856655
Email: [email protected]
PEC: [email protected]
Codice Destinatario: M5UXCR1
Netlite IT


© 2008-2019
All rights reserved.

TORNA SU